Home » Products » Load Cells » Single Point Load Cells » Brand » MICROTESS » Single Point Load Cell SP1263
Material: Aluminum
Rated Capacities:100kg-750kg
OIML R60, NTEP HB44, CPA, CE and RoHS certified
IP Rating: IP66
Suitable for single and double load cell structural platform scales
Max platform size:600*800mm
SP1263 is a typical and standard aluminum single point load cell that is with large capacity by 750kg and ideal for a wide range of weighing equipment. Environmentally sealed with potting compound to ensure reliability and durability. The industry standard size and mounting hole configuration makes the SP1263 is suitable for large-size platform by600*600mm, or as a replacement for existed weighing equipment.Except for common applications of weighing equipment, it is also can be used for force measurement for controlling.

| Parameter | Units | Specifications | |||
| Model No. | SP1263 | ||||
| Rated capacity (Emax) | kg | 100/150/200/300/500/750 | |||
| Accuracy class1)2) | C3 C6 | ||||
| Min. dead load | kg | 0 | |||
| Rated output | mV/V | 2.0 ± 0.2% | |||
| Zero balance | % of Emax | ± 2 | |||
| Repeatability error | % of AL3) | <±0.010 | <±0.005 | ||
| Creep; 30 minute | % of AL | <±0.017 | <±0.0083 | ||
| Min. dead load output return (DR); 30 min | % of AL | <±0.017 | <±0.0083 | ||
| Temp. effect on (Min. dead load output) | % of Emax/°C | <±0.0020 | <±0.0014 | ||
| Temp. effect on (Rated output2)) | % of AL/°C | <±0.0012 | <±0.0006 | ||
| Temperature range (Compensated) | °C(°F) | -10 to +40 [+14 to +104] | |||
| Temperature range (Operating) | -10 to +50 [-14 to +122] | ||||
| Temperature range (Safe storage) | -30 to +70 [-22 to +158] | ||||
| Excitation voltage (Recommended) | V AC/DC | 5 ~15 | |||
| Excitation voltage (Maximum) | 15 | ||||
| Terminal resistance (Excitation) | Ω | 403± 5 | |||
| Terminal resistance (Output) | 350 ± 3 | ||||
| Insulation resistance @50VDC | MΩ | > 5000 | |||
| Breakdown voltage | V AC | > 500 | |||
| Seal type / IP rating | potted silicon sealed /IP66 | ||||
| Load limit (Safe) | % of Emax | 150 | |||
| Load limit (Ultimate) | 300 | ||||
| Material(Spring element) | Aluminum,anodizing | ||||
| Material(Cable) | Ø5.6-4wire;PVC | ||||
| Cable length | m | 3.0 | |||
| Maximum platform size | mm | 600*600 | |||
| Offer center load error(OLML R76) | % of AL/cm | <±0.0019 | |||
| Weight; approx | kg | 1.7 | |||
| Fatigue life | cycles@Emax | >1000000 | |||
| Deflection at Emax; approx | mm | < 0.5 | |||
| Barometric pressure effect on Zero Output | Vmin/kPa | <1.0 | |||
| Mounting screw(Size/Grade) | M6/8.8 | ||||
| Mounting screw(Recommended torque) | N.m | 100-300kg:25;500-700g:30 | |||
1)Error due to the combined effect of non-linearity and hysteresis
2)The sum of errors due to Temperature Effect on Output comply with the requirements of OIML R60 and NIST HB44
3)AL = Applied Load
