Single Point Load Cell SP1041
Single Point Load Cell SP1041

Single Point Load Cell SP1041

Material: Aluminum

Rated Capacities:10kg~100kg

OIML R60, NTEP HB44, CPA, CE and RoHS certified

IP Rating: IP66

Suitable for pricing scales, counting scales, bench scales, etc

Max platform size: 400*400mm

  • Description
  • Dimensions
  • Specifications
  • Downloads
  • Production Line

SP1041 is a typical and standard aluminum single point load cell that is compact, low capacity and ideal for a wide range of weighing equipment. Environmentally sealed with potting compound to ensure reliability and durability. The industry standard size and mounting hole configuration makes the SP1041 is suitable for new equipment manufacturer or as a replacement for existed weighing equipment.

Parameter Units Specifications
Model No. SP1041
Rated capacity (Emax) kg 10/20/30/50/100
Accuracy class1)2) C3                                                   C6
Min. dead load kg 0
Rated output mV/V 2.0 ± 0.2%
Zero balance % of Emax ± 2
Repeatability error % of AL3) <±0.010 <±0.005
Creep; 30 minute % of AL <±0.017 <±0.0083
Min. dead load output return (DR); 30 min % of AL <±0.017 <±0.0083
Temp. effect on (Min. dead load output) % of Emax/°C <±0.0020 <±0.0014
Temp. effect on (Rated output2)) % of AL/°C <±0.0012 <±0.0006
Temperature range (Compensated) °C(°F) -10 to +40 [+14 to +104]
Temperature range (Operating) -10 to +50 [-14 to +122]
Temperature range (Safe storage) -30 to +70 [-22 to +158]
Excitation voltage (Recommended) V AC/DC 5 ~15
Excitation voltage (Maximum) 15
Terminal resistance (Excitation) Ω 403± 5
Terminal resistance (Output) 350 ± 3
Insulation resistance @50VDC > 5000
Breakdown voltage V AC > 500
Seal type / IP rating potted silicon sealed /IP66
Load limit (Safe) % of Emax 150
Load limit (Ultimate) 300
Material(Spring element) Aluminum,anodizing
Material(Cable) Ø5.6-4wire;PVC
Cable length m 2.0
Maximum platform size mm 400*400
Offer center load error(OLML R76) % of AL/cm <±0.0028
Weight; approx kg 0.4
Fatigue life cycles@Emax >1000000
Deflection at Emax; approx mm < 0.5
Barometric pressure effect on Zero Output Vmin/kPa <1.0
Mounting screw(Size/Grade) M6/8.8
Mounting screw(Recommended torque) N.m <50KG:10;      ≧50KG:15

Notes:

1Error due to the combined effect of non-linearity and hysteresis

2The sum of errors due to Temperature Effect on Output comply with the requirements of OIML R60 and NIST HB44

3AL = Applied Load

Related Product