Single Point Load Cell SP1320
Single Point Load Cell SP1320

Single Point Load Cell SP1320

Material: Aluminum

Rated Capacities:300kg~2t

OIML R60, NTEP HB44, CPA, CE and RoHS certified

IP Rating: IP66

Suitable for single load cell structural heavy duty platform scales

Max platform size:1200*1200mm

  • Description
  • Dimensions
  • Specifications
  • Downloads
  • Production Line

SP1263 is a typical and standard aluminum single point load cell that is with large capacity by 750kg and ideal for a wide range of weighing equipment. Environmentally sealed with potting compound to ensure reliability and durability. The industry standard size and mounting hole configuration makes the SP1263 is suitable for large-size platform by600*600mm, or as a replacement for existed weighing equipment.

Except for common applications of weighing equipment, it is also can be used for force measurement for controlling.

Parameter Units Specifications
Model No. SP1320
Rated capacity (Emax) kg 300/500/750SE 750/1000/2000
Accuracy class1)2) C3                             C6
Min. dead load kg 0
Rated output mV/V 2.0 ± 0.2
Zero balance % of Emax ± 2
Repeatability error % of AL3) <±0.010 <±0.005
Creep; 30 minute % of AL <±0.017 <±0.0083
Min. dead load output return (DR); 30 min % of AL <±0.017 <±0.0083
Temp. effect on (Min. dead load output) % of Emax/°C <±0.0020 <±0.0014
Temp. effect on (Rated output2)) % of AL/°C <±0.0012 <±0.0006
Temperature range (Compensated) °C(°F) -10 to +40 [+14 to +104]
Temperature range (Operating) -10 to +50 [-14 to +122]
Temperature range (Safe storage) -30 to +70 [-22 to +158]
Excitation voltage (Recommended) V AC/DC 5 ~15
Excitation voltage (Maximum) 15
Terminal resistance (Excitation) Ω 403± 5
Terminal resistance (Output) 350 ± 3
Insulation resistance @50VDC > 5000
Breakdown voltage V AC > 500
Seal type / IP rating potted silicon sealed /IP66
Load limit (Safe) % of Emax 150
Load limit (Ultimate) 300
Material(Spring element) Aluminum,anodizing
Material(Cable) Ø6;4wire;PVC
Cable length m 3.0
Maximum platform size mm 600*800 1200*1200
Offer center load error(OLML R76) % of AL/cm <±0.0016
Weight; approx kg 1.8 3.6
Fatigue life cycles@Emax >1000000
Deflection at Emax; approx mm < 0.5
Barometric pressure effect on Zero Output Vmin/kPa <1.0
Mounting screw(Size/Grade) M12-10.9 M16-10.9
Mounting screw(Recommended torque) N.m 98 160

Notes:

1Error due to the combined effect of non-linearity and hysteresis

2The sum of errors due to Temperature Effect on Output comply with the requirements of OIML R60 and NIST HB44

3AL = Applied Load

 

Related Product

Contact Now

    Contact Now

      CHOOSE YOUR LANGUAGE

      Contact Now