Home » Products » Load Cells » Single Point Load Cells » Brand » Microtess » Single Point Load Cell SP534A
Material: Alloy steel
Rated Capacities:150kg-2t.
Great long-term stability.
OIML R60, NTEP HB44, CE and RoHS certified·
IP Rating: IP67
Suitable for single load cell big platform scales against impact and other process weighing system.
Max platform size:1200*1200mm
SP534A is a typical and standard alloy steel single point load cell that is with large capacity by 2t and ideal for a wide range of weighing equipment. Environmentally sealed with potting black glue compound to ensure reliability and durability. The industry standard size and mounting hole configuration makes the SP534A suitable for large-size platform by 1200*1200mm, or as a replacement for existed weighing equipment.Besides for common applications of weighing equipment, it also can be used for force measurement on controlling.
Parameter | Units | Specifications | |||
Model No. | SP534A | ||||
Rated capacity (Emax) | kg | 150/250/500/1000 | 2000 | ||
Accuracy class1)2) | C3 C6 | ||||
Min. dead load | kg | 0 | |||
Rated output | mV/V | 2.0 ± 0.2 | |||
Zero balance | % of Emax | ± 2 | |||
Repeatability error | % of AL3) | <±0.010 | <±0.005 | ||
Creep; 30 minute | % of AL | <±0.017 | <±0.0083 | ||
Min. dead load output return (DR); 30 min | % of AL | <±0.017 | <±0.0083 | ||
Temp. effect on (Min. dead load output) | % of Emax/°C | <±0.0020 | <±0.0014 | ||
Temp. effect on (Rated output2)) | % of AL/°C | <±0.0012 | <±0.0006 | ||
Temperature range (Compensated) | °C(°F) | -10 to +40 [+14 to +104] | |||
Temperature range (Operating) | -40 to +65 [-40 to +149] | ||||
Temperature range (Safe storage) | -40 to +80 [-14 to +176] | ||||
Excitation voltage (Recommended) | V AC/DC | 5 ~15 | |||
Excitation voltage (Maximum) | 15 | ||||
Terminal resistance (Excitation) | Ω | 384± 5 | |||
Terminal resistance (Output) | 350 ± 3 | ||||
Insulation resistance @50VDC | MΩ | > 5000 | |||
Breakdown voltage | V AC | > 500 | |||
Seal type / IP rating | surface potting black silicon(strain gauge with special coating)/IP67 | ||||
Load limit (Safe) | % of Emax | 150 | |||
Load limit (Ultimate) | 300 | ||||
Material(Spring element) | High quality alloy steel | ||||
Material(Cable connector) | Stainless steel,electropolishing | ||||
Material(Cable) | Ø5.6;4-wire;PVC | ||||
Cable length | m | 3.0 | |||
Maximum platform size | mm | 800*800 | 1000*1000 | ||
Offer center load error(OIML R76) | % of AL/cm | <±0.0016 | |||
Weight; approx | kg | 4.0 | 4.8 | ||
Fatigue life | cycles @Emax | >1,000,000 | |||
Deflection at Emax;approx | mm | <0.5 | |||
Barometric pressure effect on Zero Output | Vmin/kPa | <1.0 | |||
Mounting screw(Size/Grade) | M14/8.8 | M16/8.8 | |||
Mounting screw(Recommended torque) | N.m | 98 | 196 |
1)Error due to the combined effect of non-linearity and hysteresis
2)The sum of errors due to Temperature Effect on Output comply with the requirements of OIML R60 and NIST HB44
3)AL = Applied Load