Single Point Load Cell SP544S
Single Point Load Cell SP544S

Single Point Load Cell SP544S

.Material: stainless steel

.Rated Capacities:50kg-500kg

OIML R60. NTEP HB44, CPA.CE and RoHS certified

IP Rating: IP68 / IP69K

Environmentally sealed by potting special black glue, also strain gauge is double-sealed with another special nanoscale coating

Suitable for stainless steel waterproof scales, process weighing control in chemical, food and pharmaceutical industries

Max platform size:300*350mm

  • Description
  • Dimensions
  • Specifications
  • Downloads
  • Production Line

SP544S is a typical and standard stainless single point load cell that is compact, low capacity and ideal for a wide range of weighing equipment. Hermetically sealing ensures reliability and durability. The industry standard size and mounting hole configuration makes the SP544S is suitable for new equipment manufacturer or as a replacement for existed weighing equipment

Parameter Units Specifications
Model No. SP544S
Rated capacity (Emax) kg 50/100/200/300 500
Accuracy class1)2) C3
Min. dead load kg 0
Rated output mV/V 2.0 ± 0.2
Zero balance % of Emax ± 1
Repeatability error % of AL3) <±0.010
Creep; 30 minute % of AL <±0.017
Min. dead load output return (DR); 30 min % of AL <±0.017
Temp. effect on (Min. dead load output) % of Emax/°C <±0.0014
Temp. effect on (Rated output2)) % of AL/°C <±0.0012
Temperature range (Compensated) °C(°F) -10 to +40 [+14 to +104]
Temperature range (Operating) -40 to +65 [-40 to +149]
Temperature range (Safe storage) -40 to +80 [-14 to +176]
Excitation voltage (Recommended) V AC/DC 5 ~15
Excitation voltage (Maximum) 15
Terminal resistance (Excitation) Ω 384± 5
Terminal resistance (Output) 350 ± 3
Insulation resistance @50VDC > 5000
Breakdown voltage V AC > 500
Seal type / IP rating Continuous sealed hermetically IP68 IP69K
Load limit (Safe) % of Emax 150
Load limit (Ultimate) 300
Material(Spring element) Stainless steel,electropolishing
Material(Cable connector) Stainless steel,electropolishing
Material(Cable) Ø5.6;4-wire;PVC
Cable length m 3.0
Maximum platform size mm 500*500 600*800
Offer center load error(OIML R76) % of AL/cm <±0.0016
Weight; approx kg 2.1
Fatigue life cycles @Emax >1,000,000
Deflection at Emax;approx mm <0.5
Barometric pressure effect on Zero Output Vmin/kPa <1.0
Mounting screw(Size/Grade) M8/8.8
Mounting screw(Recommended torque) N.m 30.0

Notes:

1Error due to the combined effect of non-linearity and hysteresis

2The sum of errors due to Temperature Effect on Output comply with the requirements of OIML R60 and NIST HB44

3AL = Applied Load

Related Product

Contact Now

    Contact Now

      CHOOSE YOUR LANGUAGE

      Contact Now