Stainless steel shear beam load cell (150kg and 300kg are bending beam load cells)
Hermetically sealed IP68
Suitable for floor scales, vehicle-test line, hopper scales and other electronic weighing devices
High accuracy
Wide range of capacities

| Specification | Value | ||||||
| Accuracy class | C3 | C5 | C6 | B10S | A5M | B10M | |
| Approval | OIML R60 C3 | OIML R60 C5 | OIML R60 C6 | ||||
| Output sensitivity ( = FS ) | mV/V | 2.0±0.004 | 3.0±0.008 | ||||
| Maximum capacity (Emax) | t | 0.1/0.15/0.2/0.25/0.3/0.5/1/1.5/2/2.5/3/5/7.5/10 | |||||
| klb | 1/1.5/2/2.5KLE/3/4/5/5KSE/7.5/10/15/20 | ||||||
| Maximum number of load cell intervals (nLC) | 3000 | 5000 | 6000 | IIIL10000
Single |
III5000
Multiple |
IIIL10000
Multiple |
|
| Ratio of minimum LC verification interval Y = Emax/vmin | 10000 | 18000 | 20000 | 10000 | 15000 | 10000 | |
| Combined error | %FS | ±0.020 | ±0.010 | ±0.009 | ±0.035 | ±0.026 | ±0.050 |
| Minimum dead load | %FS | 0 | |||||
| Safe overload | %FS | 150 | |||||
| Ultimate overload | %FS | 300 | |||||
| Zero balance | %FS | ±1.0 | |||||
| Excitation, recommended voltage | V | 5~12 (DC) | |||||
| Excitation, maximum | V | 18 (DC) | |||||
| Input resistance | Ω | 350 ± 3.5 | |||||
| Output resistance | Ω | 350 ± 3.5 | |||||
| Insulation resistance | MΩ | ≥5000 (50V DC) | |||||
| compensated Temperature | ℃ | -10 ~ +40 | |||||
| operating Temperature | ℃ | -35 ~ +65 | |||||
| Storage tempeerature | ℃ | -40 ~ +70 | |||||
| Element material | Stainless steel | ||||||
| Ingress Protection (according to EN 60529) | IP68 | ||||||
| Recommended torque on fixation | N.m | M12:75 M20:450 M24:750 | |||||
| ATEX classification (optional) | II1G Ex ia IIC T4 II1D Ex iaD 20 T73°C II3G Ex nL IIC T4 | ||||||