Nickel plated alloy steel IP67 shear beam load cell (100kg, 250kg are bending beam load cells)
Adhesive sealed
Suitable platform weighing, bed weighing, etc
High accurac
High reliability
Current calibrated (sc-option)
Specification | Value | |||||
Maximum capacity (Emax) | t | 0.5/ 1/ 2/ 2.5/ 3/ 4/ 5/ 6/ 7.5 | ||||
klb | 1/1.5/2/2.5/3/4/5/7.5/10/20 | |||||
Accuracy class | C3 | C4 | C5 | A5M | B10M | |
Approvals | OIML R60 C3 | OIML R60 C4 | OIML R60 C5 | III5000 Multiple | III10000 Multiple | |
Maximum number of load cell intervals (nLC) | 3000 | 4000 | 5000 | 5000 | 10000 | |
Ratio of minimum LC verification interval Y = Emax/vmin | 10000 | 14000 | 18000 | 15000 | 10000 | |
Combined error | %FS | ±0.020 | ±0.018 | ±0.010 | ±0.026 | ±0.050 |
Creep | %FS/30min | ±0.016 | ±0.012 | ±0.010 | ±0.017 | ±0.040 |
Temperature effect on sensitivity | %FS/10℃ | ±0.011 | ±0.009 | ±0.008 | ±0.013 | ±0.040 |
Temperature effect on zero | %FS/10℃ | ±0.015 | ±0.010 | ±0.007 | ±0.014 | ±0.020 |
Output sensitivity ( = FS ) | mV/V | 3.0±0.003 2.0±0.002 | ||||
Terminal resistance/ input | Ω | 350 ± 3.5 | ||||
Terminal resistance/ output | Ω | 350 ± 3.5 | ||||
Insulation impedance | MΩ | ≥5000 (at 50V DC) | ||||
Zero balance | %FS | ±1.0 | ||||
Compensated temperature | ℃ | -10~+40 | ||||
operating temperature | ℃ | -35~+70 | ||||
Excitation/ recommended voltage | V | 5~12 (DC) | ||||
Excitation/ maximum | V | 18 (DC) | ||||
Safe overload | of Emax | 150% | ||||
Ultimate overload | of Emax | 300% | ||||
Recommended torque on fixation | N.m | M12:100 M18:200 M24:700 | ||||
Ingress Protection (according to EN 60529) | IP67 | |||||
ATEX classification (optional) | Operating temperature ℃ -20~+40 | |||||
II1G Ex ia II C T4 II1D Ex iaD 20 T73°C II3G Ex nL IIC T4 | ||||||
“S1″Output Sensitivity is 2.0±0.002MV/V |