Aluminium-alloy IP65 single point load cell
Colourless anodized
Suitable for pricing scales, bench scales, etc
Maximum platform size: 450 x 450 mm
L6E3 is a typical and Aluminium-alloy single point load cell that is high capacity and ideal for a wide range ofweighing eauipment. Hermetically sealing ensures reliability and durability. The industry standard size and mountinohole configuration makes the L6E3 is suitable for new equipment manufacturer or as a replacement for existedweighing equipment
Specification | Value | |||
Accuracy class | OIML R60 C3 | OIML R60 C4 | OIML R60 C5 | |
Output sensitivity ( = FS ) | mV/V | 2.0±0.2 | ||
Maximum capacity (Emax) | kg | 50, 100, 150, 200, 250, 300, 400, 500 | 300, 400, 500 | |
Maximum number of load cell intervals (nLC) | 3000 | 4000 | 5000 | |
Ratio of minimum LC verification interval Y = Emax/vmin | 10000 | 15000 | 20000 | |
Combined error | %FS | ±0.0200 | ±0.015 | ±0.01 |
Minimum dead load | of Emax | 0% | ||
Safe overload | of Emax | 120% | ||
Ultimate overload | of Emax | 150% | ||
Zero balance | %FS | ±2.0 | ||
Excitation/ recommended voltage | V | 5~12 (DC) | ||
Excitation/ maximum | V | 18 V (DC) | ||
Terminal resistance/ input | Ω | 406 ± 6 | ||
Terminal resistance/ output | Ω | 350 ± 3 | ||
Insulation impedance | MΩ | ≥5000 (at 50V DC) | ||
Temperature range/ compensated | ℃ | -10 ~ +40 | ||
Temperature range/ operating | ℃ | -35 ~ +65 | ||
Storage temperature | ℃ | -40 ~ +70 | ||
Element material | Aluminium | |||
Ingress Protection (according to EN 60529) | IP65 | |||
Recommended torque on fixation bolts | N.m | M6:10 |