Stainless steel IP67 shear beam load cell (250kg is bending beam load cells)
Suitable for floor scales, automobile test facilities, hopper scales and other weighing devices
Current calibrated (sc-option)
B8D series are tvpical and hiah precision, low profile single ended shear beam, which are available ina wide range of capacities. Full stainless steel and alloy steel construction and complete hermetic sealing ensures reliableaccuracy and robustness in harsh industrial applications. The SBH series are the ideal load cell for highprecision weighing platforms with bolts by 2pcs through-holes firmly at end, meanwhile the force would be appliedfrom the self-aligning level-pin settled into the top half blind hole at the other end vertically. Also receive force viathe second half threaded hole with levelling foot together.
Specification | Value | |||
Accuracy class | OIML R60 C3 | OIML R60 C4 | OIML R60 C5 | |
Output sensitivity ( = FS ) | mV/V | 3.0±0.008 | ||
Maximum capacity (Emax) | t | 0.25, 0.5,1,2 5 | 0.25, 0.5 | |
Maximum number of load cell intervals (nLC) | 3000 | 4000 | 5000 | |
Ratio of minimum LC verification interval Y = Emax/vmin | 10000 7500 9000 | 10000 | 10000 | |
Combined error | %FS | ±0.0230 | ±0.0175 | ±0.0140 |
Safe overload | of Emax | 150% | ||
Ultimate overload | of Emax | 300% | ||
Zero balance | %FS | ±1.0 | ||
Excitation/ recommended voltage | V | 5~12 (DC) | ||
Excitation/ maximum | V | 18 V (DC) | ||
Terminal resistance/ input | Ω | 350 ± 3.5 | ||
Terminal resistance/ output | Ω | 350 ± 3.5 | ||
Insulation impedance | MΩ | ≥5000 (at 50V DC) | ||
Temperature range/ compensated | ℃ | -10 ~ +40 | ||
Temperature range/ operating | ℃ | -35 ~ +65 | ||
Storage temperature | ℃ | -40 ~ +70 | ||
Element material | Stainless steel | |||
Ingress Protection (according to EN 60529) | IP67 | |||
Recommended torque on fixation bolts | N.m | M12:75 M20:450 | ||
ATEX classification (optional) | II1G Ex ia II C T4 II1D Ex iaD 20 T73°C II3G Ex nL IIC T4 |