Nickel plated alloy steel IP68 shear beam load cell
Hermetically sealed
Suitable for electronic platform scales, hopper scales
High accuracy
Specification | Value | |
Accuracy class | C3 | |
Output sensitivity (=FS) | Mv/V | 2.0 ± 0.0040 |
Maximum capacity (Emax) | t | 0.5 / 1 / 1.5 / 2 / 3 / 5 / 10 |
Maximum number of load cell intervals (nLC) | 3000 | |
Ratio of minimum LC verification interval Y=Emax/Vmin | 10000 | |
Combined error | %FS | ±0.0230 |
Minimum dead load | %FS | 0 |
Safe overload | %FS | 150 |
Ultimate overload | %FS | 300 |
Zero balance | %FS | ±1.5 |
Excitation, recommended voltage | V | 5~12 (DC) |
Excitation maximum | V | 18 (DC) |
Input resistance | Ω | 350±3.5 |
Output resistance | Ω | 351±2.0 |
Insulation resistance | MΩ | ≧5000(50VDC) |
Compensated temperature | ℃ | -10 ~ +40 |
Operating temperature | ℃ | -35 ~ +65 |
Storage temperature | ℃ | -40 ~ +70 |
Element material | Nickel plated alloy steel | |
Ingress protection (acc. to EN 60529) | IP68 | |
Recommended torque on fixation | N.m | M12: 100, M18: 300, M24: 750 |
ATEX classification (optional) | 11G ExialCT4 II1D ExiaD 20T73° II3G Ex nL IIC T4 |