Stainless steel IP67 single point load cell
Bending beam
Suitable for belt, platform and other electronic weighing devices
Maximum platform size: for 50kg-200kg: 400 x 400 mm ; for 250kg-500kg: 600 x 800 mm for 750kg-2t: 1200 x 1200 mm
B6F is a typical and standard aluminum single point load cell that is with large capacity by 2000kg and ideal for awide range of weighing equipment. Environmentally sealed with potting compound to ensure reliability and durabilityThe industry standard size and mounting hole configuration makes the B6F is suitable for large-size platform by400*400mm,or as a replacement for existed weighing equipment.Except for common applications of weighing equipment, it is also can be used for force measurement for controling
Specification | Value | ||
Accuracy class | C3 | OIML R60 C3 | |
Output sensitivity ( = FS ) | mV/V | 2.0±0.2 | |
Maximum capacity (Emax) | kg | 100, 150, 200, 250, | 500, 750,1000,2000 |
Maximum number of load cell intervals (nLC) | 3000 | ||
Ratio of minimum LC verification interval Y = Emax/vmin | 5000 | 12000 | |
Combined error | %FS | ±0.023 | |
Safe overload | of Emax | 150% | |
Ultimate overload | of Emax | 300% | |
Zero balance | %FS | ±1.0 | |
Excitation/ recommended voltage | V | 5~12 (DC) | |
Excitation/ maximum | V | 18 V (DC) | |
Terminal resistance/ input | Ω | 385 ± 4 | |
Terminal resistance/ output | Ω | 350 ± 3.5 | |
Insulation impedance | MΩ | ≥5000 (at 50V DC) | |
Temperature range/ compensated | ℃ | -10 ~ +40 | |
Temperature range/ operating | ℃ | -35 ~ +65 | |
Storage temperature | ℃ | -40 ~ +70 | |
Element material | Stainless steel | ||
Ingress Protection (according to EN 60529) | IP67 | ||
Recommended torque on fixation bolts | N.m | M12:100(Below 500kg) M16:160(750kg-2000kg) | |
ATEX classification (optional) | II1G Ex ia II C T4 II1D Ex iaD 20 T73°C II3G Ex nL IIC T4 |