| Specification | Value | |||
| Accuracy class | C3 | OIML R60 C3 | OIML R60 C4 | |
| Output sensitivity ( = FS ) | mV/V | 2.0±0.02 | ||
| Maximum capacity (Emax) | klb | 5 | 10, 20, 30, 50, 100, 200, 250, 350, 500 | |
| Maximum number of load cell intervals (nLC) | 3000 | 3000 | 4000 | |
| Ratio of minimum LC verification interval Y = Emax/vmin | 10000 | 15000 | ||
| Combined error | %FS | ±0.023 | ±0.0174 | |
| Minimum dead load | %FS | 0 | ||
| Safe overload | %FS | 150 | ||
| Ultimate overload | %FS | 300 | ||
| Zero balance | %FS | ±1.0 | ||
| Excitation, recommended voltage | V | 5~12 (DC) | ||
| Excitation, maximum | V | 18 (DC) | ||
| input resistance | Ω | 460 ± 50 | ||
| Output resistance | Ω | 350 ± 3.5 | ||
| Insulation resistance | MΩ | ≥5000 (50V DC) | ||
| compensated Temperature | ℃ | -10 ~ +40 | ||
| operating Temperature | ℃ | -35 ~ +65 | ||
| Storage tempeerature | ℃ | -40 ~ +70 | ||
| Element material | Stainless steel | |||
| Ingress Protection (according to EN 60529) | IP68 | |||
| Recommended torque on fixation | N.m | M8:25 M10:50 | ||
| ATEX classification (optional) | Operating temperature | ℃ | -20~+40 | |
| II1G Ex ia II C T4 | II1D Ex iaD 20 T73°C | II3G Ex nL IIC T4 | ||