Double-Ended Shear Beam Load Cell  DB510A Series
Double-Ended Shear Beam Load Cell  DB510A Series

Double-Ended Shear Beam Load Cell DB510A Series

Material: Alcy steel

Rated Capacities: 15t

IP Rating: IP68

Suitable for onboard vehiclc weighing system and other electronic weighing devices

High precisior, high reliability

  • Description
  • Dimensions
  • Specifications
  • Downloads
  • Production Line

DB510A is a low-profile double ended shear bear load cells, which is designed for industrial vehicles and agricul- tural trailer high precision weighing system, Some high duty truck’s overload controlling is to ensure safe operation. The DB510A provides a very low-profile design which allows for a wide range of installation options for orboard vehicle weighing applications, Generally, the load cells are mourted between truck base chassis and upper frame, the lower profile. the more safer.

Parameter Units Specifications
Model No. DB510A
Rated capacity (Emax) t 15
Accuracy class1)2) 0.1%
Min. dead load lb 0
Rated output mV/V 3.0 ± 0.1%
Zero balance % of Emax ± 1
Repeatability error % of AL3) <±0.02
Creep; 30 minute % of AL <±0.020
Min. dead load output return (DR); 30 min % of AL <±0.020
Temp. effect on (Min. dead load output) % of Emax/°C <±0.002
Temp. effect on (Rated output2)) % of AL/°C <±0.002
Temperature range (Compensated) °C(°F) -10 to +40 [+14 to +104]
Temperature range (Operating) -40 to +65 [-40 to +149]
Temperature range (Safe storage) -40 to +80 [-14 to +176]
Excitation voltage (Recommended) V AC/DC 5 ~15
Excitation voltage (Maximum) 15
Terminal resistance (Excitation) Ω 766 ± 10
Terminal resistance (Output) 700 ± 3
Insulation resistance @50VDC > 5000
Breakdown voltage V AC > 500
Seal type / IP rating Hermetically welded / IP68
Load limit (Safe) % of Emax 200
Load limit (Ultimate) 300
Material(Spring element) Ally steel nickel plated
Material(Cable) Ø6;4-wire;PVC
Cable length m 16.0
Weight; approx kg 7.0
Fatigue life cycles @Emax >1,000,000
Deflection at Emax; approx mm < 1.5
Barometric pressure effect on Zero Output Vmin/kPa <1.0

Notes:

1Error due to the combined effect of non-linearity and hysteresis

2The sum of errors due to Temperature Effect on Output comply with the requirements of OIML R60 and NIST HB44

3AL = Applied Load