Double-Ended Shear Beam Load Cell DB958A Series
Double-Ended Shear Beam Load Cell DB958A Series

Double-Ended Shear Beam Load Cell DB958A Series

Material: Allcy steel

Rated Capacities: 10klb-200klb

OIML NTEP HB44, CE and RoHS certified

IP Ratng: IP68

Suitable for truck scale, heavy duty hopper scales and other electronic weighing devices.

High precisior by NTEP III L 10000. high reliability.

  • Description
  • Dimensions
  • Specifications
  • Downloads
  • Production Line

DB958A is a double ended shear beam. both ends loaded, center supported via self-aligning saddle structure, so that the force can be applied properly. This load cell is suitable for a wide rarge of truck scales, giant vessel scales and rail scales. It is bolted at both ends. Fully alloy steel construct, hermetically sealed, which ensure high seals perfor- mance of waterproof

Parameter Units Specifications
Model No. DB958A
Rated capacity (Emax) lbs 10K;25K;40K;50K;75K;100K;200K
Accuracy class1)2) % of Emax ±0.02
Min. dead load lb 0
Rated output mV/V 3.0 ± 0.1%
Zero balance % of Emax ± 1
Repeatability error % of AL3) <±0.05
Creep; 30 minute % of AL <±0.02
Min. dead load output return (DR); 30 min % of AL <±0.02
Temp. effect on (Min. dead load output) % of Emax/°C <±0.002
Temp. effect on (Rated output2)) % of AL/°C <±0.002
Temperature range (Compensated) °C(°F) -10 to +40 [+14 to +104]
Temperature range (Operating) -40 to +65 [-40 to +149]
Temperature range (Safe storage) -40 to +80 [-14 to +176]
Excitation voltage (Recommended) V AC/DC 5 ~15
Excitation voltage (Maximum) 15
Terminal resistance (Excitation) Ω 766 ± 5
Terminal resistance (Output) 700 ± 3
Insulation resistance @50VDC > 5000
Breakdown voltage V AC > 500
Seal type / IP rating Hermetically welded / IP68
Load limit (Safe) % of Emax 150
Load limit (Ultimate) 200
Material(Spring element) Ally steel nickel plated
Material(Cable) Ø6;4-wire;PVC
Cable length ft 10k…40k 50k…200k
40.0 52.5
Weight; approx lb 10k-25k  40k 50k-75k 100k-125k       200k
8       13       19 40 100
Fatigue life cycles @Emax >1,000,000
Deflection at Emax; approx mm < 1.5

Notes:

1Error due to the combined effect of non-linearity and hysteresis

2The sum of errors due to Temperature Effect on Output comply with the requirements of OIML R60 and NIST HB44

3AL = Applied Load