Home » Products » Load Cells » Beam Load Cells » Double Ended Beam Load Cells » Brand » Microtess » Double-Ended Shear Beam Load Cell DB903A Series
Material: Alcy steel
Rated Capacities: 15t
IP Rating: IP68
Suitable for onboard vehiclc weighing system and other electronic weighing devices
High precisior, high reliability
DB510A is a low-profile double ended shear bear load cells, which is designed for industrial vehicles and agricul- tural trailer high precision weighing system, Some high duty truck’s overload controlling is to ensure safe operation. The DB510A provides a very low-profile design which allows for a wide range of installation options for orboard vehicle weighing applications, Generally, the load cells are mourted between truck base chassis and upper frame, the lower profile. the more safer.
Parameter | Units | Specifications | |||
Model No. | DB903A | ||||
Rated capacity (Emax) | klb | 10/20/30/50/75/100/150/250 | |||
Accuracy class1)2) | 0.03% | ||||
Min. dead load | lb | 0 | |||
Rated output | mV/V | 3.0 ± 0.1% | |||
Zero balance | % of Emax | ± 1 | |||
Repeatability error | % of AL3) | <±0.010 | |||
Creep; 30 minute | % of AL | <±0.020 | |||
Min. dead load output return (DR); 30 min | % of AL | <±0.020 | |||
Temp. effect on (Min. dead load output) | % of Emax/°C | <±0.0014 | |||
Temp. effect on (Rated output2)) | % of AL/°C | <±0.0012 | |||
Temperature range (Compensated) | °C(°F) | -10 to +40 [+14 to +104] | |||
Temperature range (Operating) | -40 to +65 [-40 to +149] | ||||
Temperature range (Safe storage) | -40 to +80 [-14 to +176] | ||||
Excitation voltage (Recommended) | V AC/DC | 5 ~15 | |||
Excitation voltage (Maximum) | 15 | ||||
Terminal resistance (Excitation) | Ω | 766 ± 10 | |||
Terminal resistance (Output) | 700 ± 3 | ||||
Insulation resistance @50VDC | MΩ | > 5000 | |||
Breakdown voltage | V AC | > 500 | |||
Seal type / IP rating | Hermetically welded / IP68 | ||||
Load limit (Safe) | % of Emax | 140 | |||
Load limit (Ultimate) | 200 | ||||
Material(Spring element) | Ally steel nickel plated | ||||
Material(Cable) | Ø6;4-wire;PVC | ||||
Cable length | m | 10-30klb | 50-250klb | ||
12.0 | 16.0 | ||||
Weight; approx | lb | 10k-20k | 30k-75k | 100k 150k 250k | |
7 | 18 | 28 34 90 | |||
Fatigue life | cycles @Emax | >1,000,000 | |||
Deflection at Emax; approx | mm | < 1.5 | |||
Barometric pressure effect on Zero Output | Vmin/kPa | <1.0 |
1)Error due to the combined effect of non-linearity and hysteresis
2)The sum of errors due to Temperature Effect on Output comply with the requirements of OIML R60 and NIST HB44
3)AL = Applied Load