Single-Ended Beam load cell B530S/B570S
Single-Ended Beam load cell B530S/B570S

Single-Ended Beam load cell B530S/B570S

Material:Stainless steel

Greatlong-term stability.

Rated Capacities :O.5~5t

IP Rating:IP68

OIMLR60, NTEP HB44,CE and RoHS certified

B730S with 17-4PH material and PEEK strain gauge from HBK.

Suitable for platform scales, dosing system and process control in chemical, food, pharmaceutical and other industries.

High precision by OIML R60 C5, higher liability.

  • Description
  • Dimensions
  • Specifications
  • Downloads
  • Production Line

The B530, B730 series are typical and highprecision, low profile single-ended shear beam, which are available in a wide range of capacities. Full stainless steelconstruction and complete hermetic sealing ensures reliable accuracy and robustness in harsh industrial applications. The B530, B730 are the ideal load cell for high precision weighing.Platforms with bolts by 2pcs through-holes firmly at end, meanwhile the force would be applied from the self-aligning level-pin settled into the blind hole at the other end vertically.

Parameter Units Specifications
Model No. B530S / B730S
Rated capacity (Emax) t 0.5; 1 2 3 5
Accuracy class1)2) C3                            C5
Min. dead load kg 0
Rated output mV/V 2.0 ± 0.002
Zero balance % of Emax ± 1
Repeatability error % of AL3) < ± 0.010                                         < ± 0.006
Creep; 30 minute % of AL < ± 0.017                                      < ± 0.010
Min. dead load output return (DR); 30 min % of AL < ± 0.017                                      < ± 0.010
Temp. effect on (Min. dead load output) % of Emax/°C < ± 0.0020                                   < ± 0.0014
Temp. effect on (Rated output2)) % of AL/°C < ± 0.0012                                   < ± 0.0007
Temperature range (Compensated) °C(°F) -10 to +40 [+14 to +104]
Temperature range (Operating) -40 to +65 [-40 to +149]
Temperature range (Safe storage) -40 to +80 [-14 to +176]
Excitation voltage (Recommended) V AC/DC 5 ~15
Excitation voltage (Maximum) 15
Terminal resistance (Excitation) Ω 384 ± 5
Terminal resistance (Output) 350 ± 3
Insulation resistance @50VDC > 5000
Breakdown voltage V AC > 500
Seal type / IP rating Hermetically welded / IP68 IP69k
Load limit (Safe) % of Emax 150
Load limit (Ultimate) 300
Material(Spring element) Stainless steel [B730S:17-4PH]
Material(Strain gauge) PEEK[B730S:HBK SG]
Material(Cable) Ø5.4;4-wire;PVC
Cable length m 5.0
Weight; approx kg 0.5; 1t 2t 3t 5t
1.0 1.4 1.8 4.0
Fatigue life cycles @Emax >1,000,000
Deflection at Emax; approx mm < 0.5
Barometric pressure effect on Zero Output Vmin/kPa <1.0
Mounting screw(Size/Grade) Size/Grade M12 / A2-70 M12 / A2-70 M14 / A2-70 M18 / A2-70
Mounting screw(Recommended torque) N.m 98 120 140 275

Notes:

1Error due to the combined effect of non-linearity and hysteresis

2The sum of errors due to Temperature Effect on Output comply with the requirements of OIML R60 and NIST HB44

3AL = Applied Load

Related Product