Single Point Load Cell SP547S
Single Point Load Cell SP547S

Single Point Load Cell SP547S

Material: stainless steel

Rated Capacities: 60kg~200kg

OIML R60, NTEP HB44, CPA, CE and RoHS certified

IP Rating: IP68 /IP69K

Hermetically sealing, also strain gauge is double-sealedwith another special nanoscale coating

Suitable for stainless steel waterproof scales, processweighing control in chemical, food and pharmaceuticalindustries

Max platform size: 400*500mm

  • Description
  • Dimensions
  • Specifications
  • Downloads
  • Production Line

SP547S is a typical and standard stainless single point load cell that is high capacity and ideal for a wide range ofweighing eauipment. Hermetically sealing ensures reliability and durability. The industry standard size and mountinohole configuration makes the SP547S is suitable for new equipment manufacturer or as a replacement for existedweighing equipment

SIZE

Parameter Units Specifications
Model No. SP547S
Rated capacity (Emax) kg 60/100/200
Accuracy class1)2) C3 C5
Min. dead load kg 0
Rated output mV/V 1.8 ± 0.2
Zero balance % of Emax ± 2
Repeatability error % of AL3) <±0.010 <±0.006
Creep; 30 minute % of AL <±0.017 <±0.010
Min. dead load output return (DR); 30 min % of AL <±0.017 <±0.010
Temp. effect on (Min. dead load output) % of Emax/°C <±0.0020 <±0.0014
Temp. effect on (Rated output2)) % of AL/°C <±0.0012 <±0.0007
Temperature range (Compensated) °C(°F) -10 to +40 [+14 to +104]
Temperature range (Operating) -10 to +65 [-14 to +149]
Temperature range (Safe storage) -30 to +80 [-40 to +176]
Excitation voltage (Recommended) V AC/DC 5 ~15
Excitation voltage (Maximum) 15
Terminal resistance (Excitation) Ω 384± 5
Terminal resistance (Output) 350 ± 3
Insulation resistance @50VDC > 5000
Breakdown voltage V AC > 500
Seal type / IP rating Hermetically welded /IP68 IP69K
Load limit (Safe) % of Emax 150
Load limit (Ultimate) 300
Material(Spring element) Stainless steel
Material(Cable connector) Stainless steel
Material(Cable) Ø5.6;4-wire;PVC
Cable length m 3.0
Maximum platform size mm 400*500
Offer center load error(OIML R76) % of AL/cm <±0.0025
Weight; approx kg 1.4
Fatigue life cycles @Emax >1,000,000
Deflection at Emax;approx mm <0.5
Barometric pressure effect on Zero Output Vmin/kPa <1.0
Mounting screw(Size/Grade) M6/8.8
Mounting screw(Recommended torque) N.m 20.0

Notes:

“Error due to the combined effect of non-linearity and hysteresis* The sum of errors due to Temperature Effect on Output comply with the reguirements of OlML R60 and NIST HB44″AL = Applied Load

size1