Single Point Load Cell SP1260
Single Point Load Cell SP1260

Single Point Load Cell SP1260

Material: Aluminum

Rated Capacities: 100kg~750kg

OIML R60, NTEP HB44., CPA, CE and RoHS certified

IP Rating: IP66

Suitable for single and double load cell structuralplatform scales

Max platform size: 600*800mm

  • Description
  • Dimensions
  • Specifications
  • Downloads
  • Production Line

SP1260 is a typical and standard aluminum single point load cell that is with large capacity by 750kg and ideal for awide range of weighing equipment. Environmentally sealed with potting compound to ensure reliability and durabilityThe industry standard size and mounting hole configuration makes the SP1260 is suitable for large-size platform by600*600mm,or as a replacement for existed weighing equipment.Except for common applications of weighing equipment, it is also can be used for force measurement for controling

SP1260 SIZE

Parameter Units Specifications
Model No. SP1260
Rated capacity (Emax) kg 100/200/300/500/750
Accuracy class1)2) C3 C6
Min. dead load kg 0
Rated output mV/V 2.0 ± 0.2
Zero balance % of Emax ± 2
Repeatability error % of AL3) <±0.010 <±0.005
Creep; 30 minute % of AL <±0.017 <±0.0083
Min. dead load output return (DR); 30 min % of AL <±0.017 <±0.083
Temp. effect on (Min. dead load output) % of Emax/°C <±0.0020 <±0.0014
Temp. effect on (Rated output2)) % of AL/°C <±0.0012 <±0.0006
Temperature range (Compensated) °C(°F) -10 to +40 [+14 to +104]
Temperature range (Operating) -10 to +50 [+14 to +122]
Temperature range (Safe storage) -30 to +70 [-22 to +158]
Excitation voltage (Recommended) V AC/DC 5 ~15
Excitation voltage (Maximum) 15
Terminal resistance (Excitation) Ω 403± 5
Terminal resistance (Output) 350 ± 3
Insulation resistance @50VDC > 5000
Breakdown voltage V AC > 500
Seal type / IP rating Potted silicon sealed /IP66
Load limit (Safe) % of Emax 150
Load limit (Ultimate) 300
Material(Spring element) Aluminum,anodizing
Material(Cable connector) Stainless steel,electropolishing
Material(Cable) Ø5.6;4-wire;PVC
Cable length m 3.0
Maximum platform size mm 600*800
Offer center load error(OIML R76) % of AL/cm <±0.0016
Weight; approx kg 1.8
Fatigue life cycles @Emax >1,000,000
Deflection at Emax;approx mm <0.5
Barometric pressure effect on Zero Output Vmin/kPa <1.0
Mounting screw(Size/Grade) M8/8.8
Mounting screw(Recommended torque) N.m 100-250kg:25; 500-750kg:30

Notes:

“Error due to the combined effect of non-linearity and hysteresis
“The sum of errors due to Temperature Effect on Output comply with the requirements of OlML R60 and NIST HB44
“AL= Applied Load