Home » Products » Load Cells » Compression Load Cells » Brand » Microtess » Compression Load Cell R510S
Material: Stainless steel
Rated Capacities:1t~100t
OIML R60, NTEP HB44, CPA, CE and RoHS certified
IP Rating: IP68,IP69K
Suitable for process weighing of hopper scales, silo scales, tank scales
High precision by OIML R60 C5, high reliability
R510S is a low-profile compression load cell, it is compact and high precision. It is widely suitable for applications in the food and chemicals industry, it is with smooth electro-polished surfaces so that it is easy to be cleaned, and is ideally suited to weighing applications in clean-in-place/sterilize-in-place environments. Full stainless steel constructure, completely hermetically sealed by laser. Also it is designed with mandrel with self-aligning arc point to receive force vertically to ensure the high force accuracy.
Parameter | Units | Specifications | |||
Model No. | R510S | ||||
Rated capacity (Emax) | t | 1/2.5/5/10/15/20/30/50/100 | |||
Accuracy class1)2) | C3 C5 | ||||
Min. dead load | kg | 0 | |||
Rated output | mV/V | 2.0 ± 0.004 | |||
Zero balance | % of Emax | ± 1 | |||
Repeatability error | % of AL3) | <±0.010 <±0.006 | |||
Creep; 30 minute | % of AL | <±0.017 <±0.010 | |||
Min. dead load output return (DR); 30 min | % of AL | <±0.017 <±0.010 | |||
Temp. effect on (Min. dead load output) | % of Emax/°C | <±0.0018 <±0.0014 | |||
Temp. effect on (Rated output2)) | % of AL/°C | <±0.0012 <±0.0007 | |||
Temperature range (Compensated) | °C(°F) | -10 to +40 [+14 to +104] | |||
Temperature range (Operating) | -40 to +65 [-40 to +149] | ||||
Temperature range (Safe storage) | -40 to +80 [-14 to +176] | ||||
Excitation voltage (Recommended) | V AC/DC | 5 ~15 | |||
Excitation voltage (Maximum) | 60 | ||||
Terminal resistance (Excitation) | Ω | 766± 10 | |||
Terminal resistance (Output) | 700 ± 3 | ||||
Insulation resistance @50VDC | MΩ | > 5000 | |||
Breakdown voltage | V AC | > 500 | |||
Seal type / IP rating | Hermetically welded / IP68 IP69k | ||||
Load limit (Safe) | % of Emax | 150 | |||
Load limit (Ultimate) | 300 | ||||
Material(Spring element) | Stainless steel | ||||
Material(Cable) | Ø6;4-wire;PVC | ||||
Cable length | m | 1-10t | 15-100t | ||
6.0 | 12.0 | ||||
Weight; approx | kg | 1-10t 15-20t | 30t 50-100t | ||
1.5 2.0 | 3.5 7.0 | ||||
Fatigue life | cycles @Emax | >1,000,000 | |||
Deflection at Emax; approx | mm | < 1.0 |
1)Error due to the combined effect of non-linearity and hysteresis
2)The sum of errors due to Temperature Effect on Output comply with the requirements of OIML R60 and NIST HB44
3)AL = Applied Load