Canister Compression Load Cell P520SD
Canister Compression Load Cell P520SD

Canister Compression Load Cell P520SD

Material: Stainless steel

Rated Capacities:30t~50t

Compensation mode: active compensation for non-linearity, creep, hysteresis, ZTC, STC, etc.

Advanced quick Protocol CANopen by 125 kbit/sec.

OIML R60, NTEP HB44, CPA, CE and RoHS certified

IP Rating IP68,IP69K

Suitable for truck scales, heavy duty hopper scales, force measurement equipment.

High precision by OIML R60 C6, high reliability

  • Description
  • Dimensions
  • Specifications
  • Downloads
  • Production Line

The P520SD is a typical digital high-precision canister compression load cell with double-cut faces against rotation. The P520SD is fully hermetically sealed with stamped integrated canister; which enable it to work in the harshest conditions. A rocker column design ensures optimum weighing accuracy when subjected to off-center and side forces when the scale deck is moving back and forth, meanwhile left and right.

Parameter Units Specifications
Model No. P520SD
Load cell type Column Compression(Digital)
Rated capacity (R.C)4) t 30                     40                     50
Sensitivity at R.C d@R.C.4) 300.000         400.00         500.000
Communication Controller Area Network(CAN),Encrypted
Communication rate kbit/sec 125
Accuracy class C3            C4           C6
Min. dead load kg 50
Zero balance % of Emax ± 0.1
Repeatability error % of AL3) <±0.010                  <±0.007                  <±0.005
Creep; 30 minute % of AL <±0.0176                 <±0.0125                <±0.0083
Min. dead load output return (DR); 30 min % of AL <±0.0176                 <±0.0125                <±0.0083
Temp. effect on (Min. dead load output) % of Emax/°C <±0.0014                 <±0.0014                <±0.0007
Temp. effect on (Rated output2)) % of AL/°C <±0.000117             <±0.0009                <±0.0006
Temperature range (Compensated) °C(°F) -10 to +40 [+14 to +104]
Temperature range (Operating) -40 to +65 [-40 to +149]
Temperature range (Safe storage) -40 to +80 [-14 to +176]
Excitation voltage (Recommended) VDC 12 or 24
Excitation voltage (Maxmum/Maximum) 7.5 /28
Lightning protection A >80.000
Breakdown voltage integral
Insulation resistance @50VDC > 5000
Breakdown voltage V AC > 500
Protection(Type) Hermetically welded
Protection(IP rating) IP68/69K
Load limit (Safe dynamic load) % of Emax 70
Load limit (Safe) 200
Load limit (Ultimate) 300
Material(Spring element) Stainless steel
Material(Enclosure) 304 stainless,laser welded
Material(Connectors) Iintegral
Material(Strain gauge) Poiyamide
Material(Cable) Ø6.0;4-wire;PVC
Cable length(cell to cell) m 16.0
Cable length(Network) Junction boxes
Weight; approx kg 6.0
Fatigue life cycles @Emax >1,000,000
Deflection at Emax; approx mm <0.5               <0.6                 <0.7
Barometric pressure effect on Zero Output Vmin/kPa <1.0

Notes:

1Error due to the combined effect of non-linearity and hysteresis

2) The sum of errors due to Temperature Effect on Output comply with the requirements of OIML R60 and NIST HB44

3)AL = Applied Load

4) R.C. = Rated Capacity