Stainless steel IP68 compression load cell
Hermetically sealed
Suitable for vehicle and hopper scales and vehicle testing facilities
Built in surge arrestors
High accuracy
Current calibrated (sc-option)

| Specification | Value | |||
| Accuracy class | C3 | OIML R60 C3 | OIML R60 C4 | |
| Output sensitivity ( = FS ) | mV/V | ±0.002 | ||
| Maximum capacity (Emax) | t | 0,5,1,2,3,5 | 10,20,25,30,40,50 | |
| Maximum number of load cell intervals (nLC) | 3000 | 4000 | ||
| Ratio of minimum LC verification interval Y = Emax/vmin | 10000 | 15000 | ||
| Combined error | %FS | ±0.023 | ±0.0174 | |
| Minimum dead load | t | 0 | ||
| Safe overload | of Emax | 150% | ||
| Ultimate overload | of Emax | 300% | ||
| Zero balance | %FS | ±1.0 % | ||
| Excitation, recommended voltage | V | 5~12 V DC | ||
| Excitation, maximum | V | 18 V DC | ||
| Terminal resistance, input | Ω | 700 ± 7 | ||
| Terminal resistance, output | Ω | 703 ± 4 | ||
| Insulation impedance | MΩ | ≥5000 (at 50V DC) | ||
| Temperature range, compensated | ℃ | -10 ~ +40 | ||
| Temperature range, operating | ℃ | -35 ~ +65 | ||
| Element material | Stainless steel | |||
| Ingress Protection (according to EN 60529) | IP68 | |||
| ATEX classification (optional) | II1G Ex ia II C T4 | II1D Ex iaD 20 T73°C | II3G Ex nL IIC T4 | |