Alloy steel, nickel-plated, single point bending beam, hermetically welded, tension or compression
Ingress protection (according to EN 60529): IP68
Suitable for belt scales, hopper scales and other electronic weighing devices
Specification | Value | |||
Maximum capacity (Emax) | kg | 5/10/20/30/50/75/100/150/200/250/300/350/400/500 | ||
Accuracy class | C3 | |||
Maximum number of Verification intervals | N.max | 3000 | ||
Maximum number of load cell intervals (nLC) | Vmin | Emax/10000 | ||
Combined error | %FS | ±0.020 | ||
Creep | %FS/30min | ±0.016 | ||
Temperature effect on sensitivity | %FS/10℃ | ±0.011 | ||
Temperature effect on zero | %FS/10℃ | ±0.015 | ||
Output sensitivity ( = FS ) | mV/V | 2.0±0.002 | ||
Terminal resistance, input | Ω | 460 ± 50 | ||
Terminal resistance, output | Ω | 350 ± 3.5 | ||
Insulation impedance | MΩ | ≥5000 (at 50V DC) | ||
Zero balance | %FS | ±1.0 | ||
Temperature compensated | ℃ | -10 ~ +40 | ||
Temperature range, operating | ℃ | -35 ~ +70 | ||
Excitation, recommended voltage | V | 5~12(DC) | ||
Excitation, maximum | V | 18(DC) | ||
Safe overload | of Emax | 150 | ||
Ultimate overload | of Emax | 300 | ||
ATEX class (optional) | II1G Ex ia II C T4 | II1D Ex iaD 20 T73°C | II3G Ex nL IIC T4 |