Home » Products » Load Cells » Beam Load Cells » S-Beam Load Cells » Brand » Microtess » S-Beam Load Cell S525A Series
Material: Alloy steel (Metric thread)
Rated Capacity:50kg~3t
OIML R60, NTEP HB44,CPA, CE and RoHS certified
IP Rating: IP66 / IP68
Suitable for process weighing of hopper scales, silo scales, tank scales, also force measurement.
High precision by OIML R60 C5, high reliability
S525 is a square-shaped tension & compression load cell, compact and low-profile, suitable for installation in restricted space, completely hermetically sealed by laser to ensure it can work in harsh environment. Available in a wide range of capacities from 50kg to 3t
Parameter | Units | Specifications | |||
Model No. | S525A | ||||
Rated capacity (Emax) | kg/t | 50;100;200;300;500;1000/2;3 | |||
Accuracy class1)2) | C3 C5 | ||||
Min. dead load | kg | 0 | |||
Rated output | mV/V | 3.0 ± 0.002 | |||
Zero balance | % of Emax | ± 1 | |||
Repeatability error | % of AL3) | <±0.010 <±0.006 | |||
Creep; 30 minute | % of AL | <±0.017 <±0.010 | |||
Min. dead load output return (DR); 30 min | % of AL | <±0.017 <±0.010 | |||
Temp. effect on (Min. dead load output) | % of Emax/°C | <±0.0020 <±0.0014 | |||
Temp. effect on (Rated output2)) | % of AL/°C | <±0.0012 <±0.0007 | |||
Temperature range (Compensated) | °C(°F) | -10 to +40 [+14 to +104] | |||
Temperature range (Operating) | -40 to +65 [-40 to +149] | ||||
Temperature range (Safe storage) | -40 to +80 [-14 to +176] | ||||
Excitation voltage (Recommended) | V AC/DC | 5 ~15 | |||
Excitation voltage (Maximum) | 15 | ||||
Terminal resistance (Excitation) | Ω | 384± 5 | |||
Terminal resistance (Output) | 350 ± 3 | ||||
Insulation resistance @50VDC | MΩ | > 5000 | |||
Breakdown voltage | V AC | > 500 | |||
Seal type / IP rating | Cap.≤1000kg:Silicon rubber/IP66 | ||||
Cap.≤2t:Hermetically welded/IP68 | |||||
Load limit (Safe) | % of Emax | 150 | |||
Load limit (Ultimate) | 300 | ||||
Material(Spring element) | Alloy steel nickel plated | ||||
Material(Cable) | Ø5.6;4-wire;PVC | ||||
Cable length | m | 5.0 | |||
Weight; approx | kg | 50-100kg 2t 3t | |||
0.8 1.6 2.4 | |||||
Fatigue life | cycles @Emax | >1,000,000 | |||
Deflection at Emax; approx | mm | < 0.5 | |||
Barometric pressure on Zero Output | Vmin/kPa | < 1.0 |
1)Error due to the combined effect of non-linearity and hysteresis
2)The sum of errors due to Temperature Effect on Output comply with the requirements of OIML R60 and NIST HB44
3)AL = Applied Load