Material: Alloy steel ( thread)
Rated Capacity: 1KN~10KN
Calibrated based on criterion of ISO 376
IP Rating: IP66
Suitable for force measurement and overloading safety controlling
High precision by ISO 376 class 0.5, 1, 2.
S515 is a square-shaped tension & compression load cell, high-quality silica gel potting is to ensure it can work in harsh environment. Available in a wide range of capacities from 1KN to 10KN
Parameter | Units | Specifications | |||
Model No. | S515A | ||||
Rated capacity (Emax) | KN | 1/2/5/10 | |||
Accuracy class1)2) | 0.5 00 | ||||
Min. dead load | kg | 0 | |||
Rated output | mV/V | 3.0 ± 0.003 | |||
Zero balance | % of Emax | ± 1 | |||
Repeatability error | % of AL3) | <±0.010 <±0.006 | |||
Creep; 30 minute | % of AL | <±0.017 <±0.010 | |||
Min. dead load output return (DR); 30 min | % of AL | <±0.017 <±0.010 | |||
Temp. effect on (Min. dead load output) | % of Emax/°C | <±0.0020 <±0.0014 | |||
Temp. effect on (Rated output2)) | % of AL/°C | <±0.0012 <±0.0007 | |||
Temperature range (Compensated) | °C(°F) | -10 to +40 [+14 to +104] | |||
Temperature range (Operating) | -40 to +65 [-40 to +149] | ||||
Temperature range (Safe storage) | -40 to +80 [-14 to +176] | ||||
Excitation voltage (Recommended) | V AC/DC | 5 ~15 | |||
Excitation voltage (Maximum) | 15 | ||||
Terminal resistance (Excitation) | Ω | 384± 5 | |||
Terminal resistance (Output) | 350 ± 3 | ||||
Insulation resistance @50VDC | MΩ | > 5000 | |||
Breakdown voltage | V AC | > 500 | |||
Seal type / IP rating | Silicon rubber/IP66 | ||||
Load limit (Safe) | % of Emax | 140 | |||
Load limit (Ultimate) | 200 | ||||
Material(Spring element) | Alloy steel nickel plated | ||||
Material(Cable) | Ø5.6;4-wire;PVC | ||||
Cable length | m | 5.0 | |||
Weight; approx | kg | 1-5kN | 10klb | ||
0.8 | 1.0 | ||||
Fatigue life | cycles @Emax | >1,000,000 | |||
Deflection at Emax; approx | mm | < 1.0 | |||
Barometric pressure on Zero Output | Vmin/kPa | < 1.0 |
1)Error due to the combined effect of non-linearity and hysteresis
2)The sum of errors due to Temperature Effect on Output comply with the requirements of OIML R60 and NIST HB44
3)AL = Applied Load