Home » Products » Load Cells » Load Pin Load Cells » Load Pin Load Cells LP510S Series
Material: Stainless steel
Rated Capacities: 1 ton – 10 ton
Through-hole to accommodate strain gauge
IP Rating: IP69K
Suitable for force measurement device and safetycontrolling against overload
Excellent sealing performance
Load Pin Load Cells LP510S Series is a special double ended shear beam load cell. lts sharp is pin and it’s with throughout-hole to accommodate strain gauge instead of typical side 4pcs cavities which improve sealing performance significantly and not easy damaged in harsh environment.
Parameter | Units | Specification |
Model No. | LP510S | |
Rated capacity (Emax) | kN | 90kN |
Min. dead load | kg | 0 |
Rated output | mV/V | 1.0 ± 0.5% |
Zero balance | % of Emax | ± 1 |
Combined error1)2) | % of Emax | ≤ ± 0.5 |
Repeatability error | % of AL3) | ≤ ± 0.3 |
Creep; 30 minute | % of AL | ≤ ± 0.1 |
Min. dead load output return (DR); 30 min |
% of AL | ≤ ± 0.1 |
Temp. effect on Min. dead load output |
% of Emax/°C | ≤ ± 0.005 |
Temp. effect on Rated output2) | % of AL/°C | ≤ ± 0.01 |
Temperature range (Compensated) | °C (°F) | -10 to +40[+14 to + 140] |
Temperature range (Operating) | -30 to +65 [-22 to +149] | |
Temperature range (Safe storage) | -40 to +80 [-40 to +176] | |
Excitation voltage (Recommended) | V AC/DC | 5 ~ 15 |
Excitation voltage (Maximum) | V AC/DC | 20 |
Terminal resistance (Excitation) | Ω | 382 ± 10 |
Terminal resistance (Output) | Ω | 350 ± 3 |
Insulation resistance @50VDC | MΩ | >5000 |
Breakdown voltage | V AC | >500 |
Seal type / IP rating | Hermetically welded / IP68 | |
Load limit (Safe) | % of Emax | 300 |
Load limit (Ultimate) | % of Emax | 500 |
Material (Spring element) | Stainless steel | |
Material (Cable) | Φ6; 4-wire; PVC | |
Cable length | m | 3.0 |
Weight; approx | kg | 1.6 |
Fatigue life | cycles @Emax | >1,000,000 |
Deflection at Emax; approx | mm | < 0.5 |
1) Error due to the combined effect of non-linearity and hysteresis
2) The sum of errors due to Temperature Effect on Output comply with the requirements of OlML R60 and NIST HB44
3) AL = Applied Load