Color screen display:Certification accuracy: 6000e,7″TFT full color touch screen
Compact structure:Panel structure convenient to embed in electrical cabinet
Common Communication interface:Standard isolated RS232 and isolated
RS485; CAN, LAN,discrete I/O port,4 inputs and 4 outputs.Optional analog output, 4~20mA/0~10V; discrete I/O port, 8 inputs and 8 outputs.
PLC fieldbus interface:Profibus-DP,CC-Link, Profinet, EtherNet/IP, Modbus-RTU, Modbus-TCP
Typical application:basic weighing, check weighing, filling/dosing,lose-in-weigh application programming.
EM212 is an industrial process control weight indica-tor, even don’t collect to PLC, it can work as a standalone controller with the 7″ color LCD and sufficient discrete 1/O ports.it can provide abundant humanized HMI interface, convenient for the special weighing applications as a controller.
Parameter | Specification |
Product model | EM212 |
AC Power | 100-240VAC |
Operating temperature | -20 ~ +60 |
Display screen | 7″TFT full color screen |
Number of verification scale intervals (e) | 6000 |
Number of scale intervals for indicator (d) | 100000 |
Number of sensors | Up to 6 350 Ohm load cells(2 or 3mV/V) |
AD sampling rate | 1000Hz |
Load cell Excitation | 5VDC |
Minimum sensitivity | 0.5 µV/e |
Accuracy class | III |
KeyPad | 4 key control |
Communication protocol | Command output, Continuous output, Modbus RTU,Modbus TCP |
Calibration method | Weight calibration,Weight-free calibration; Remote calibration |
Scale | 1 |
Capacity | 1-500,000kg (default 60) |
Increment size | 0.0001/0.0002/0.0005 |
0.001/0.002/0.005 | |
0.01/0.02/0.05 (default 0.01) | |
0.1/0.2/0.5 | |
1/2/5 | |
10/20/50/100 | |
Baud rate | 1200,2400,4800,9600(default),19200,38400,57600,115200 |
DIO interface | 4 inputs (optocoupler isolation)/4 outputs(relays,transistors) |
Serial | 1 way RS485 multiplex (isolation) |
1 way RS232(isolation) | |
1 way CAN(isolation) | |
Ethernet interface※ | Port rate 10Mbps/100Mbps adaptive |
Analog quantity※ | 1 way 4-20mA or 0-10v |
DIO interface expansion board※ | 8 input (optocoupler isolation) / 8 outputs (relay contact) |
Communication interface board※ | PROFINET、EtherNet/IP、Profibus-DP、CC-Link |