Home » Products » Weigh Modules » Weigh Module MDB916-1A
Double-ended shear beam design, center loaded
Self–aligning, smart design facilitate module to be bolted directly to tank leg without requiring additional mounting plates or load buttons
Capacities (per module): 2.5Klb-75Klb
Alloy steel and stainless steel optional
Assembled with double-ended shear beam DB916A
The MDB916-1A weigh module is with perfect level of performance in tank and hopper weighing applications MDB916-1A Series kit is ideally suited for indoor and outdoor process weighing system in the medium- to high-capacity ranges. Each module incorporates self-checking capabilities for thermal expansion and contraction. Also welds between parts are very smooth and strong
Parameter | Units | Specifications | |||
Weighing Model No. | MDB916A-1A | ||||
Weighing Module Material | Alloy steel with nickel plated | ||||
Load Cell Model No | DB916A | ||||
Rated capacity(Emax) | kg | 2.5/5/10/20/35/50/75 | |||
Rated output | mV/V | 3.0± 0.003 | |||
Zero balance | % of Emax | ± 1 | |||
Accuracy class1)2) | 0.03% | ||||
Repeatability error | % of AL3) | <±0.010 | |||
Creep; 30 minute | % of AL | <±0.020 | |||
Min. dead load output return (DR); 30 min | % of AL | <±0.020 | |||
Temp. effect on (Min. dead load output) | % of Emax/°C | <±0.0014 | |||
Temp. effect on (Rated output2)) | % of AL/°C | <±0.0012 | |||
Temperature range (Compensated) | °C(°F) | -10 to +40 [+14 to +104] | |||
Temperature range (Operating) | -40 to +65 [+40 to +149] | ||||
Temperature range (Safe storage) | -40 to +80 [+40 to +176] | ||||
Excitation voltage (Recommended) | V AC/DC | 5 ~15 | |||
Excitation voltage (Maximum) | 15 | ||||
Terminal resistance (Excitation) | Ω | 766± 5 | |||
Terminal resistance (Output) | 700 ± 3 | ||||
Insulation resistance @50VDC | MΩ | > 5000 | |||
Breakdown voltage | V AC | > 500 | |||
Seal type / IP rating | Hermetically welded / IP68 | ||||
Load limit (Safe) | % of Emax | 140 | |||
Load limit (Ultimate) | 200 | ||||
Cable length | m | 2.5-5klb 10-35klb 50-75klb | |||
6.0 12.0 16.0 | |||||
European/OIML Approval(Cetificate Number) | |||||
European/OIML Approval(Class) | |||||
NTEP Approval(Cetificate Number) | |||||
NTEP Approval(Class) |
1)Error due to the combined effect of non-linearity and hysteresis
2)The sum of errors due to Temperature Effect on Output comply with the requirements of OIML R60 and NIST HB44
3)AL = Applied Load