Capacity: 5-50t
Steel ball loading, strong restoration ability
Easy complete installation, high weighing accuracy
OIML C3 certificate
Alloy Steel, stainless steel
The Keli QS series sensors feature a double-ended shear beam design, ideal for truck scales, railway scales, batching scales, and various other weighing applications. They ensure high precision, stability, and durability for complex industrial weighing needs.
Outline Dimension | ||||||||||||||
Rated capacity(t) | L | L1 | L2 | L3 | W | W1 | W2 | H | H1 | H2 | C1 | C2 | C3 | C4 |
5 | 224 | 125 | 80 | 45 | 135 | 100 | 10 | 168.8 | 11 | 20 | Φ68 | Φ30 | Φ18 | Φ50.8 |
10、15、20、25、30 | 240 | 125 | 80 | 45 | 135 | 100 | 10 | 223.5 | 11 | 20 | Φ85~88 | Φ30 | Φ18 | Φ75 |
40 | 240 | 125 | 80 | 45 | 135 | 100 | 10 | 239.5 | 11 | 20 | Φ88 | Φ30 | Φ18 | Φ75 |
50 | 340 | 160 | 124 | 45 | 160 | 124 | 10 | 260 | 11 | 20 | Φ98 | Φ40 | Φ22 | Φ75 |
Parameter | Specification |
Rated capacity | 5-50t |
Rated output | 2.0±0.002mv/v |
Combined error | ±0.03% F.S |
Non-repeatability | ±0.02% F.S |
Non-linearity | ±0.02% F.S |
Hysteresis error | ±0.02% F.S |
Zero balance | ±1% F.S |
Creep error (30 minutes) | ±0.02% F.S |
Temperature effect on zero | ±0.02% F.S |
Temperature effect on output | ±0.02% F.S |
Compensated temperature range | -10 ~ +40℃ |
Operating temperature range | -30 ~ +70℃ |
Maximum safe overload | 150% OF R.C |
Ultimate safe overload | 200% OF R.C |
Recommended Excitation | 10 ~ 12V DC |
Maximum Excitation | 15V DC |
Environment protection | IP68 |
Input impedance | 750±10Ω |
Output impedance | 702±3Ω; 703±5Ω (cable≥15m) |
Insulation resistance at 50V DC | ≥5000MΩ |
Material | alloy steel, stainless steel |
Cable | length 5.2m(5t), 8m(10t), 10m(15t), 10/12m(20t), 12/16m(25-50t); diameter 6mm |