Load Cell Calibration: Essential Methods and Best Practices

Recently updated on August 21st, 2024 at 08:05 am

Load cells are important for accurate weight measurement, but continuous use and environmental factors can degrade their performance. This guide covers calibration methods, best practices, and troubleshooting tips to help you maintain reliable load cell performance and ensure precise results. Regular calibration is key to operational efficiency.

Load Cell Calibration

What is Load Cell Calibration?

Load cell calibration is the process of verifying and adjusting the accuracy of a load cell’s measurements. Over time, factors such as mechanical wear, environmental conditions, and electrical interference can cause a load cell’s readings to drift or become inaccurate.

To ensure that a load cell provides precise measurements, calibration involves comparing the load cell’s output to a known reference or standard. This comparison helps identify any discrepancies between the actual force applied and the load cell’s output signal.

The goal of calibration is to correct these discrepancies by adjusting the load cell’s output to match the known reference. This ensures that the load cell remains accurate and reliable in its measurements.

Regular calibration is essential, especially in industries where precise weight measurement is critical. By maintaining the accuracy of load cells through calibration, you can ensure the consistency and quality of your processes.

Methods of Load Cell Calibration

Load cell calibration can be performed using various methods, each suited to different applications and levels of accuracy. Here are the most common methods:

Deadweight Calibration

Deadweight calibration is one of the most accurate and widely used methods. It involves applying known weights to the load cell and recording the corresponding output. Here’s how it works:

  • Initial Load: The vessel or load cell is evenly loaded to 10% of its live load capacity using standard weights. The weight indication is recorded, and the weights are then removed.
  • Material Addition: Next, process material is added to the vessel until the weight indicator registers the same (10%) weight as it did with the calibration weights.
  • Incremental Loading: The calibration weights are reloaded on the vessel, and the new reading (now about 20%) is recorded. This process is repeated, incrementally increasing the load until 100% of the capacity is reached.

This method is preferred when high accuracy is required, as it directly compares the load cell’s reading to a precise standard.

Live Weight Calibration

Live weight calibration is a faster alternative to deadweight calibration, using pre-weighted individuals as calibration weights instead of standard weights. The procedure follows these steps:

  • Identical Procedure: The process is similar to deadweight calibration, with known weights being replaced by pre-weighed people.
  • Safety Consideration: This method should only be used when there is no risk of injury, as the use of live individuals introduces variability and potential hazards.

While this method is quicker, it may introduce variability due to the inconsistency of live objects, making it less accurate than deadweight calibration.

Material Transfer Calibration

Material transfer calibration involves transferring a known quantity of material (such as grains or liquids) to the load cell and measuring the weight. This method is useful when dealing with bulk materials but may be less accurate due to potential loss or variation in material during transfer. It’s typically used in industries where direct weight application is challenging.

Master Cell Calibration

Master cell calibration involves using a highly accurate reference load cell, typically three times more precise than the load cell being calibrated, to ensure accurate measurements. The process includes applying force incrementally, either through a hydraulic system or a servomotor, and comparing the output signals of both the master and the calibrated load cells at each step to verify accuracy.

Best Practices for Load Cell Calibration

Proper load cell calibration is essential for ensuring accurate and reliable measurements. Adhering to best practices not only helps maintain accuracy but also extends the lifespan of the load cell. Below are some key practices to follow:

1. Choose the Right Calibration Method

Each method of calibration has its own advantages and limitations, making it important to choose the right one based on your specific needs. For example, deadweight calibration is ideal for high-precision needs, while material transfer calibration might be more practical in industrial settings where direct loading is challenging.

2. Calibrate at Regular Intervals

Regular calibration is essential to maintain accuracy. The frequency of calibration should be based on the load cell’s usage, the criticality of the measurements, and any industry standards or regulations. For heavily used load cells, more frequent calibration may be necessary to ensure continued reliability. Many load cell users adopt an annual calibration as the standard interval to ensure that measurements are always as accurate as possible.

3. Document the Calibration Process

Always document the calibration process thoroughly. Record the date, time, method used, and the technician performing the calibration. Include details of the load cell’s performance before and after calibration. Proper documentation ensures traceability and accountability, which are critical in maintaining measurement standards.

4. Consider Environmental Factors

Environmental conditions can significantly affect load cell performance. Temperature, humidity, and vibrations are some factors that can lead to measurement errors. During calibration, ensure that the environment is stable and consistent with the conditions in which the load cell will be used. Adjust the calibration process as necessary to account for these factors.

5. Perform Zero Balance Calibration

Zero balance calibration is an important step to ensure that the load cell reads zero when no load is applied. This process involves adjusting the load cell’s output to zero, ensuring that any subsequent measurements are accurate. This step is especially important when the load cell is installed in a new environment or after any significant changes in its setup.

6. Validate Calibration Results

After completing the calibration, validate the results by testing the load cell with known weights or forces. This step confirms that the load cell is operating within its specified tolerances and provides reliable measurements. If any discrepancies are found, further adjustments may be necessary.

7. Use High-Quality Calibration Equipment

The accuracy of your calibration depends on the quality of the calibration equipment used. Ensure that you are using certified and well-maintained equipment that meets the required standards. High-quality calibration tools reduce the risk of introducing errors during the calibration process. For example, When performing deadweight calibration, one of the most critical pieces of equipment is the calibration weights themselves. To ensure accuracy, these weights should be certified to a high standard, such as Class F1 or F2 weights, which are commonly used in industrial settings for precise calibration. Another important piece of equipment is a precision balance or reference scale used during material transfer calibration.

8. Implement Safety Protocols

Safety is paramount during the calibration process. Ensure that all personnel involved are trained and aware of potential hazards, especially when using live weight calibration. Follow all safety protocols to prevent accidents and ensure the integrity of the calibration process.

Common Issues in Load Cell Calibration

Despite careful planning and execution, several issues can arise during load cell calibration that may affect the accuracy and reliability of the measurements. Below are some common problems and how to address them:

Issue Description Causes Solutions
Zero Shift Deviation in the load cell’s output when no load is applied. Temperature changes, mechanical stress, electrical interference. Check mounting and wiring; recalibrate using known reference; consider temperature compensation.
Non-Linearity Deviations in the load cell’s output as the applied load increases, resulting in an output that doesn’t follow a straight line. Improper calibration, mechanical stress, electrical interference. Recalibrate with appropriate weights; inspect mounting; apply multiple calibration points.
Hysteresis Variations in output readings when the applied load is increasing and decreasing. Material creep, mechanical stress, insufficient calibration. Secure mounting; apply load uniformly; calibrate using multiple load cycles.
Temperature Sensitivity Variations in output readings due to changes in temperature affecting the load cell’s mechanical and electrical properties. Environmental temperature changes. Use temperature compensation techniques; calibrate at different temperatures; install in a controlled environment.
Electrical Noise and Interference Disruption of the load cell’s signal due to electrical noise from nearby equipment or electromagnetic fields. Power sources, nearby electrical equipment, electromagnetic fields. Use shielded cables and grounding; locate load cell away from interference sources; consider signal conditioning.
Inadequate Calibration Equipment Errors introduced by using low-quality or uncertified calibration equipment. Using non-certified weights, worn-out reference scales. Use high-quality, certified equipment; ensure regular maintenance and recalibration of tools.
Creep Load cell output changes slightly over time even after the load has remained constant. Material properties, mechanical stress over time. Allow time for stabilization; account for creep during calibration.
Inconsistent Load Application Inaccuracies due to load not being applied consistently or uniformly during calibration. Off-center or non-uniform load application. Ensure controlled, consistent load application; design calibration setup to distribute load evenly.
Drift Over Time Gradual change in load cell output due to mechanical wear, environmental conditions, or aging components. Mechanical wear, aging, environmental factors. Regular recalibration; monitor performance over time; adjust calibration intervals as needed.
Mechanical Interference Inaccurate readings due to misalignment, improper mounting, or external vibrations. Misalignment, external forces, vibrations. Proper installation and securing; ensure no external forces or vibrations affect calibration.

This table provides a concise overview of the common issues in load cell calibration, their causes, and recommended solutions.

Conclusion

Accurate load cell calibration is vital for ensuring reliable measurements in various applications. Regular calibration and validation are key to maintaining this accuracy, preventing issues like drift, zero shift, and non-linearity. By following best practices and addressing common issues, you can ensure the long-term reliability and precision of your load cells. For a complete understanding of load cells, their operation, and troubleshoots, visit our Load Cell Guide.