Home » Products » Load Cells » Canister Compression Load Cells » Canister Compression Load Cell CTMC
Material: Alloy steel, stainless steel optional
Rated Capacities:20t~50t
IP Rating: IP68
The CTMC series is a typical and standard cost-efficient canister compression load cell with compact and robust machined canister. The CTMC is fully hermetically sealed with upper and base convers; which enable it to work in the harshest conditions. A rocker column design ensures optimum weighing accuracy when subjected to off-center and side forces when the scale deck is moving back and forth, meanwhile left and right.
Item | Unit | Parameter | |||
Accuracy class to OIML R60 | C2 | C3 | |||
Maximum capacity (Emax) | t | 20 | 30 | 40 | 50 |
Minimum LC verification interval (Vmin) | % of Emax | 0.0200 | 0.01 | ||
Sensitivity (Cn) | mV/V | 2.0+0.002 / 0+0.02 | |||
Zero balance | mV/V | 2.0+0.002 / 0+0.02 | |||
Temperature effect on zero balance (TKo) | % of Cn/10K | ±0.02 | ±0.0170 | ||
Temperature effect on sensitivity (TKc) | % of Cn/10K | ±0.02 | ±0.0170 | ||
Hysteresis error (dhy) | % of Cn | ±0.0270 | ±0.0180 | ||
Non-linearity (dlin) | % of Cn | ±0.0250 | ±0.0167 | ||
Creep (dcr) over 30 min | % of Cn | ±0.030 | ±0.0167 | ||
Input (RLc) & Output resistance (Ro) | Ω | 700 ±20 & 703 ±3.5 | |||
Nominal range of excitation voltage (Bu) | V | 5~12 | |||
Insulation resistance (Ris) at 50 Vdc | MΩ | >5000 | |||
Service temperature range (Bt) | °C | -30 ~ +70 | |||
Safe load limit (EL) & Breaking load (Ed) | % of Emax | 150&250 | |||
Protection class according to EN60 529 (IEC 529) | IP68 | ||||
Material: Measuring element+housing | Stainless or alloy steel+Stainless steel | ||||
Maximum capacity (Emax) | t | 20 | 30 | 40 | 50 |
Weight (G), approx | kg | 3.2 | 3.6 | 3.6 | 3.8 |
Deflection at Emax (snom), approx. | mm | 0.65 | 0.75 | 0.85 | 0.85 |
Cable: Diameter :Φ5mm Length | m | 12 | 14 | 16 | 16 |
Min.scale verification(emin) according to En45501 […#=max.Number of load cells] |
kg | 5 | 10 | 10 | 10 |
[6#] | [6#] | [4#] | |||
10 | [8#] | 20 | 20 | ||
[8#] | [8#] | [10#] | |||
Recommended maximum weighing capacity of scale | t | 50 | 100 | 120 | 100 |
80 | 150 | 200 |